The Aprilaire Model 60 is a digital humidifier control designed for precise humidity management in homes. It features automatic operation, a change water panel indicator, and compatibility with Aprilaire humidifiers, ensuring efficient and convenient whole-house humidity control.

Installation Requirements

The Aprilaire Model 60 requires a 220-240V, 4A, 50/60Hz power supply and compatibility with existing HVAC systems. It must be installed in the cold air return duct or on an interior wall, ensuring proper wiring and high voltage precautions are followed.

Pre-Installation Requirements and Compatibility Check

Before installing the Aprilaire Model 60, ensure compatibility with your HVAC system and humidifier. Verify the voltage requirement of 220-240V, 4A, 50/60Hz, and check if the control is suitable for your specific Aprilaire humidifier model, such as the Model 800.

Inspect the installation location, ensuring it is either the cold air return duct or an interior wall. Verify that the area is accessible for wiring and water supply connections. Ensure proper ductwork and space for the control unit and water panel.

Review the installation manual to confirm all components are included and undamaged. Check for any local building codes or regulations that may apply. If unsure, consult a licensed HVAC professional to avoid installation issues. Proper preparation ensures a smooth and safe installation process.

Step-by-Step Installation Guide

Begin by disconnecting the power supply to the HVAC system for safety. Remove the knob and cover from the Aprilaire Model 60 control unit to access the wiring terminal. Connect the wires according to the wiring diagram in the manual, ensuring proper connections for power, humidity sensor, and blower activation.

Mount the control unit in the cold air return duct or on an interior wall, ensuring it is level and securely fastened. Connect the water supply line to the humidifier, following the manufacturer’s instructions for proper sizing and routing. Set the control to the “Test/Reset” position to verify proper operation.

Once installed, set the desired humidity level using the control knob. Test the system by running the HVAC fan to ensure the humidifier activates correctly. Refer to the manual for detailed wiring and installation specifics to ensure a safe and functional setup.

Operating Instructions

Set the desired humidity level using the control knob. Monitor the system and adjust settings based on outdoor temperatures. Use the “Test/Reset” position to ensure proper functionality and prevent over-humidification.

Setting Up the Humidifier Control

Start by installing the Manual Humidifier Control in the cold air return duct or on an interior wall. Ensure proper wiring connections as outlined in the installation manual. Once installed, set the desired humidity level using the control knob. The system will automatically adjust to maintain the selected humidity. Monitor the yellow “Change Water Panel” light, which flashes when maintenance is needed. For optimal performance, adjust settings based on outdoor temperatures and humidity levels. Test the system by turning the control knob to the “Test/Reset” position to ensure all functions operate correctly. Regularly check and maintain the system to prevent over-humidification and ensure efficient operation.

Understanding and Adjusting Humidity Controls

The Aprilaire Model 60 features a Manual Humidifier Control that allows you to set and maintain your desired humidity level. To ensure optimal performance, adjust the control knob based on outdoor temperatures and indoor humidity levels. Lower settings are recommended during colder months to prevent window condensation, while higher settings may be needed in drier conditions. The control includes a yellow “Change Water Panel” indicator, which flashes when maintenance is required. Regularly monitor and adjust the humidity level to prevent over-humidification or dryness. For accurate control, consider the system’s built-in sensor, which helps maintain consistent humidity. Test the system by turning the control knob to the “Test/Reset” position to ensure proper operation. Adjust settings seasonally or based on room size for optimal comfort and efficiency. Always refer to the manual for specific guidelines and troubleshooting tips to maintain your home’s humidity levels effectively.

Maintenance and Care

Regular maintenance is essential for optimal performance. Replace the water panel as indicated by the yellow flashing light. Clean the humidifier and control annually to ensure efficiency and prevent mineral buildup or mold growth.

Cleaning and Upkeep of the Humidifier

Regular cleaning is crucial to maintain the efficiency and longevity of your Aprilaire Model 60 humidifier. Begin by turning off the power and water supply to the unit. Remove and soak the water panel in a mixture of water and vinegar to eliminate mineral deposits. Use a soft brush to gently scrub away any stubborn buildup. Check and clean the humidifier’s drain to ensure proper water flow and prevent clogs. Wipe down the exterior with a damp cloth to remove dust and debris. Additionally, inspect the solenoid and other internal components for signs of wear or corrosion, replacing them if necessary. Repeat this process every 3 to 6 months, or as recommended in the user manual, to keep your humidifier functioning optimally and prevent mold growth.

Replacing the Water Panel

Replacing the water panel in your Aprilaire Model 60 humidifier is essential for maintaining its performance and preventing bacterial growth. Start by turning off the power and water supply to the unit. Locate the water panel, typically found in the humidifier’s base. Open the unit according to the manufacturer’s instructions, which may involve removing screws or clips. Gently pull out the old water panel, taking care not to spill any remaining water. Dispose of the old panel responsibly. Insert the new water panel, ensuring it is properly seated and aligned. Close the unit and restore the water supply and power. Check for leaks and test the humidifier to ensure it operates smoothly. The yellow “Change Water Panel” light on the control should reset once the new panel is installed. Replace the water panel every 3 to 6 months, or as indicated by the control’s indicator light, to maintain ideal humidity levels and system efficiency.

Troubleshooting Common Issues

If the yellow “Change Water Panel” light on your Aprilaire Model 60 flashes, it indicates the water panel needs replacement. Ensure the water supply is turned off before replacing the panel. If the humidifier is not producing water, check the solenoid valve for proper operation and verify that the water supply is connected correctly. If the humidity levels are inconsistent, inspect the sensor for accuracy or recalibrate it as needed. Faulty sensors or incorrect installations can lead to poor performance. If issues persist, refer to the manual for detailed diagnostic steps or contact a certified technician. Always ensure the HVAC blower is operating when testing the humidifier. Regular maintenance, such as cleaning and replacing parts, can prevent many common problems. By addressing these issues promptly, you can restore optimal functionality to your Aprilaire Model 60 humidifier and maintain a comfortable indoor environment.

By following the installation, operation, and maintenance guidelines outlined in the Aprilaire Model 60 user manual, you can ensure optimal performance from your humidifier. Regular cleaning and timely replacement of the water panel are crucial for maintaining efficiency and preventing mold growth. Always monitor humidity levels and adjust settings according to seasonal changes to avoid over-humidification. If issues arise, refer to the troubleshooting section for quick solutions. For best results, schedule annual professional inspections to ensure your system operates smoothly. Proper care and attention will extend the lifespan of your Aprilaire Model 60, providing consistent comfort and improved indoor air quality for years to come.